1.5 踢脚线
1.5.1 水泥砂浆踢脚线
项目编码:011105001 项目名称:水泥砂浆踢脚线
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/33_02.jpg?sign=1738857242-2tiOUjaUewxbMI7JCTdXkdzer8Xi7NcH-0-289533799d0be6a97d5b4cca3efb68bf)
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/33_03.jpg?sign=1738857242-v6H9eLXeBS3bJnXKBk2lhesLGDrA4LPq-0-b627f666e47c05d6dd6d43955693121e)
【例1-21】已知某房间踢脚线如图1-21所示,墙厚为240mm,室内踢脚线为150mm高的水泥砂浆踢脚线,底层为1∶3水泥砂浆底层,面层为1∶2水泥砂浆,试根据清单工程量计算规则计算水泥砂浆踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/33_04.jpg?sign=1738857242-7VA0dqizYZJUGrvvq9tS5xyo2CqwQcNt-0-5ef5d1e923c45d92b8857de4fddfa44c)
图1-21 水泥砂浆踢脚线平面及三维示意图
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/34_01.jpg?sign=1738857242-XZv6iYTzJ2rj6cIqRRFXZvetNaQgZkUq-0-dcf4d0f9c1743f856ca402191dcceeab)
图1-21 水泥砂浆踢脚线平面及三维示意图(续)
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/34_02.jpg?sign=1738857242-k0N35x9y1TeZaHRUvzwWS6nIWjhODR2i-0-78e2f91c9c051e9e6f06b670fce768f7)
注意:不扣除门洞口的长度,洞口侧壁也不增加。房屋内楼地面面积计算算至内墙内边线。
1.5.2 石材踢脚线
项目编码:011105002 项目名称:石材踢脚线
【例1-22】已知某房间踢脚线如图1-22所示,墙厚为240mm,门洞口尺寸都为900mm×2100mm,采用石材踢脚线,踢脚线高度为150mm,试根据清单工程量计算规则计算石材踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/35_01.jpg?sign=1738857242-gWItCitQdtmsJXH7CIU8ijpqRjl3cQKJ-0-d7cf886a9a13485b59985addbae0c514)
图1-22 石材踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/35_02.jpg?sign=1738857242-QlBqIWrUw0ZwtGqDM4GM4dTE7r0BzH5u-0-a38e8ab170262f9d01236ee69ae2d4a5)
1.5.3 块料踢脚线
项目编码:011105003 项目名称:块料踢脚线
【例1-23】已知某建筑物采用块料踢脚线如图1-23所示,墙厚为240mm,M1的尺寸为1000mm×2100mm,踢脚线高度为200mm,试根据清单工程量计算规则计算块料踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/36_01.jpg?sign=1738857242-iIRBvnlfkVxmddqfOtKc1IBxpgElVWEP-0-13658e576140860f5707f3449f7e90c5)
图1-23 块料踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/36_02.jpg?sign=1738857242-RmVQrjcRQ9AIlEslrohgdW0utLqse4d5-0-84bd295c4a57858a0fbcf9be2024369f)
1.5.4 塑料板踢脚线
项目编码:011105004 项目名称:塑料板踢脚线
【例1-24】某房间内塑料板踢脚线如图1-24所示,墙厚为240mm,踢脚线高度为150mm,M1的尺寸为1200mm×2400mm,M2的尺寸为1000mm×2100mm,试根据清单工程量计算规则计算塑料板踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/37_01.jpg?sign=1738857242-yBor7vzo3LwNTexhYOmTfA5diTfwJP2e-0-82474d91bef32469ce7a11bafbc422ca)
图1-24 塑料板踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/37_02.jpg?sign=1738857242-SjkSG3ZtYO4AjkQRo6tyhOLR5vMGoINC-0-a23909bf7d21eda79a5a91bf1ac0293e)
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/38_01.jpg?sign=1738857242-jLFPcywxI3IRTtfm4I9fRMURw3wnkFtY-0-8d07070b8ad7c1dea8a72f377898b3d4)
1.5.5 木质踢脚线
项目编码:011105005 项目名称:木质踢脚线
【例1-25】某房间内踢脚线为木质踢脚线,踢脚线高为150mm,墙厚为240mm,如图1-25所示,M1的尺寸为1200mm×2400mm,试根据清单工程量计算规则计算木质踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/38_02.jpg?sign=1738857242-tmtWXL6e2S6i5bmJ7PuotdA57UAeHB7j-0-61c557b535e9e81f2d1399ad4d1d087d)
图1-25 木质踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/38_03.jpg?sign=1738857242-OC0FW0IpyjZSTuYmYPFOjfUVdYrvupfU-0-491b6e7b09e82ecea4467a4ae2964334)
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/39_01.jpg?sign=1738857242-COIyfxN9y0dOyMUhR5YDQI7Iyx1ckEjC-0-471fa9c306bf105f29514d4ba9418325)
1.5.6 金属踢脚线
项目编码:011105006 项目名称:金属踢脚线
【例1-26】某房屋金属踢脚线如图1-26所示,墙厚为240mm,M1的尺寸为900mm×2100mm,踢脚线高为150mm,试根据清单工程量计算规则计算金属踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/39_02.jpg?sign=1738857242-pxcSH5psqTY2LOsg1kWOuxo5bSx8gqxi-0-5b86d1f29dd2ff46a3f776f0ec683727)
图1-26 金属踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/40_01.jpg?sign=1738857242-2B37Sx8jSo4pzXviDjzx41PdDt1kmhmu-0-3303eb93ad3ca23d9b7d8fb4a1154dbb)
1.5.7 防静电踢脚线
项目编码:011105007 项目名称:防静电踢脚线
【例1-27】某建筑房屋为防静电踢脚线,如图1-27所示,墙厚为240mm,踢脚线高为150mm,M1的尺寸为1200mm×2100mm,M2的尺寸为1000mm×2100mm,试根据清单工程量计算规则计算防静电踢脚线工程量。
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/40_02.jpg?sign=1738857242-kb7NaTlvSCrOOigjnuDivNh3HvK0xsz7-0-214ed3955eff5634c1f320b8d486c3fa)
图1-27 防静电踢脚线平面及三维示意图
【解】
![](https://epubservercos.yuewen.com/A032B8/17977545708665006/epubprivate/OEBPS/Images/41_01.jpg?sign=1738857242-G7Tl3WjvK6sG3F0GrDugHZqtbo6NwBYr-0-d485a8470373990e15b38b4f22f9e775)